maheri.com

Alireza Maheri Personal Website Home | About me | Research | Publications | Taught subjects and Tutorials | Downloadable documents | Calculators

  Calculators >> Steady flow in pipes in series-Problem type 3

Steady flow in pipes-Pipes in series
Unknown pipe diameter

To learn how to use this calculator click here

Volume Flow Rate And Fluid Properties
Volume Flow Rate Q(lit/s)ViscosityDensity (kg/m^3)
Absolute (Pa.s)
Kinematic (m^2/s)
Pipe Segment With Unknown Diameter
Total length l(m)Total KRoughness e(mm)
Inlet Pipe Segment Connection Fitting Valve Shaft (Pump/Turbine) Outlet
Inlet
Elevation z(m)Pressure P(kPa)Velocity V(m/s) OR
Diameter D(mm)
GageVelocity
Diameter
AbsoluteAttached To The Pipe With Unknown Diameter
Length l(m)Diameter D(mm)Roughness e(mm)
KDiameter D(mm)
(Pipe Size)
Shaft Head (m)
Pump
Turbine
Outlet
Elevation z(m)Pressure P(kPa)Velocity V(m/s) OR
Diameter D(mm)
GageVelocity
Diameter
AbsoluteAttached To The Pipe With Unknown Diameter

Result:




By: Alireza Maheri, June 2001

  Calculators >> Steady flow in pipes in series-Problem type 3

Home | About me | Research | Publications | Taught subjects and Tutorials | Downloadable documents | Calculators